800-874-2811 | Contact Us
       
  • Language

PORTACOUNT RESPIRATOR FIT TESTER

Fire service and law enforcement employees face unknown chemical hazards. That's why they must use the highest rated respirators, including SCBAs and military-quality gas masks. Healthcare organizations prefer N95 filtering facepiece (disposable) respirators for protecting workers against airborne biohazards such as TB and SARS. Industrial companies have employees using a wide variety of respirators. But the highest protection level can't be achieved if the respirator isn't donned properly.

That's where the TSI PORTACOUNT® Respirator Fit Tester comes in. Passing a quantitative respirator fit test proves that the facepiece is sized correctly and that the person knows how to put it on correctly. The PORTACOUNT® Pro+ Respirator Fit Tester is the only instrument with built-in N95 technology to perform a quantitative fit test on an N95 respirator.

Abandon the tedious and ambiguous qualitative respirator fit test methods such as Saccharin and Bitrex and have peace of mind knowing that you can trust your fit test results.

Features and Benefits

  • Measures fit factors greater than 10,000
  • Computes respirator fit factor using microscopic particles in ambient air
  • Stand-alone operation, no external computer required
  • New faster fit testing times (Pro+)
  • Simpler and Easier to use
  • OSHA-compliant for all respirators, including N95 (Pro+)
  • Color touch screen lets you operate the instrument with a touch of your finger, a pen or stylus
  • Automates fit testing with FitPro™ Fit Test Software
  • Optional Card Printer allows you to print employee fit test cards
  • Optional mask sampling adapters allow fit testing with employee's own mask
  • Interactive training tool for initial and follow-up training

Applications

  • Quantitative respirator fit testing (QNFT)
  • Disposable filtering-facepiece fit testing (series 100, 99, 95, P1, P2)
  • Half-mask fit testing
  • Full-face fit testing
  • Gas mask fit testing
  • PAPR fit testing
  • SCBA fit testing

To request information on TSI's PortaCount® Respirator Fit Testers including instrument literature, a system demonstration, a quotation, etc., please click here.

TSI offers a comprehensive training program, the PortaCount Academy. To enroll or request more information, click here.

PORTACOUNT Respirator Fit Tester 8030

The PORTACOUNT® Pro Respirator Fit Tester is the easy way to reliably fit test any tight-fitting respirators.

PORTACOUNT Respirator Fit Tester 8038

The PORTACOUNT® Pro+ Fit Tester can be used to fit test ANY tight-fitting respirator including N95, P2 and P1 disposables.

Fit Test Adapters Model 8025

TSI Model 8025 Fit Test Adapters provide an easy, practical alternative to the probed method of quantitative respirator fit testing.

Fit Test Probe Kit Model 8025-N95™

Use the TSI Model 8025-N95 Fit Test Probe Kit along with your PORTACOUNT® Pro and Pro+ Respirator Fit Testers to quantitatively fit test filtering-facepiece (disposable) respirators.

FitPro™ Fit Test Software

FitPro™ Fit Test software makes fit testing simple and foolproof. Included with every PORTACOUNT Pro and Pro+ Respirator Fit Tester, the fit test program automatically leads you through the fit test protocol step by step.

Particle Generator Model 8026

TSI offers an accessory for enhancing ambient particle counts.

BROCHURES

 For First Responders - PORTACOUNT
 For First Responders - PORTACOUNT
 For First Responders - PORTACOUNT
 For First Responders - PORTACOUNT
 For First Responders - PORTACOUNT
 For First Responders - PORTACOUNT (A4)
 For Healthcare Professionals PORTACOUNT
 For Healthcare Professionals PORTACOUNT
 For Healthcare Professionals PORTACOUNT
 For Healthcare Professionals PORTACOUNT
 For Healthcare Professionals PORTACOUNT
 For Healthcare Professionals PORTACOUNT (A4)
 For Industrial and Healthcare Workers - PORTACOUNT
 For Industrial and Healthcare Workers - PORTACOUNT
 For Industrial and Healthcare Workers - PORTACOUNT
 For Industrial and Healthcare Workers - PORTACOUNT
 For Industrial and Healthcare Workers - PORTACOUNT
 For Industrial and Healthcare Workers - PORTACOUNT (A4)
 PortaCount Academy
 PortaCount Academy
 TSI Knows Nanoparticle Measurement
 TSI Knows Nanoparticle Measurement (A4)

SPEC SHEETS

 FITPRO Software and Card Printer
 FITPRO Software and Card Printer
 FITPRO Software and Card Printer
 Model 8025-N95 Fit Test Probe Kit (Kit de sonde pour test d’adéquation) A4 FR
 Model 8025-N95 Fit Test Probe Kit A4 DE
 Model 8025-N95 Fit Test Probe Kit A4 ES
 Model 8025-N95 Fit Test Probe Kit A4 SE
 Model 8025-N95 Fit Test Probe Kit US
 Model 8026 Générateur de particules A4 FR
 Model 8026 Particle Generator A4 DE
 Model 8026 Particle Generator A4 ES
 Model 8026 Particle Generator A4 SE
 Model 8026 Particle Generator US
 Model 8030 PORTACOUNT PRO Respirator Fit Tester A4 DE
 Model 8030 PORTACOUNT PRO Respirator Fit Tester A4 ES
 Model 8030 PORTACOUNT PRO Respirator Fit Tester A4 SE
 Model 8030 PORTACOUNT PRO Respirator Fit Tester A4 UK
 Model 8030 PORTACOUNT PRO Respirator Fit Tester US
 Model 8030 Testeur d’adéquation des masques respiratoires PORTACOUNT PRO A4 FR
 Model 8038 PORTACOUNT PRO+ Respirator Fit Tester A4 DE
 Model 8038 PORTACOUNT PRO+ Respirator Fit Tester A4 ES
 Model 8038 PORTACOUNT PRO+ Respirator Fit Tester A4 SE
 Model 8038 PORTACOUNT PRO+ Respirator Fit Tester A4 UK
 Model 8038 PORTACOUNT PRO+ Respirator Fit Tester US
 Model 8038 Testeur d’adéquation des masques respiratoires PORTACOUNT PRO+ A4 FR

SERVICE INFORMATION

APPLICATION NOTES

 A Comparison of Respirator Fit Factors Determined by Portable Condensation Nuclei Counting and Forward Light-Scattering Photometric Methods (ITI-020)
 Don't Use Qualitative Fit Testing for Full-face Respirators (ITI-032)
 Evaluation of the TSI PORTACOUNT for Quantitative Respirator Fit Testing (ITI-018)
 Faster OSHA-compliant Fit Testing (ITI-081)
 Fit Factors vs Protection Factors (ITI-023)
 Fit Testing Using Size-Selected Aerosol (ITI-062)
 Help your staff get the most out of their N95 respirators with the PORTACOUNT® Respirator Fit Tester (ITI-102)
 Help your staff get the most out of their N95 respirators with the PORTACOUNT® Respirator Fit Tester (ITI-102-A4)
 How to Quantitatively Fit Test Filtering-facepiece Respirators Using a TSI PORTACOUNT Plus and N95-Companion (ITI-054)
 Hygienic Security and The PORTACOUNT (ITI-034)
 Introduction to Respirator Fit Testing (ITI-070)
 Leakage Measurements on Wearers of Respiratory Protective Equipment with Facial Hair/Beards/Spectacles: Summary of a Literature Search (ITI-028)
 Mechanisms of Filtration for High Efficiency Fibrous Filters (ITI-041)
 Mechanisms of Filtration for High Efficiency Fibrous Filters (ITI-041-A4)
 N95-Companion Model 8095 Theory of Operation (ITI-053)
 Occupational Health Risks Associated with the Use of Irritant Smoke for Qualitative Fit Testing of Respirators (ITI-040)
 Penetration of Ambient Aerosols Through Respirator Faceseal Leaks (ITI-055)
 PORTACOUNT PRO Model 8030 Respirator Fit Tester Theory of Operation (RFT-002)
 PORTACOUNT PRO Model 8030 Respirator Fit Tester Theory of Operation (RFT-002-A4)
 PORTACOUNT PRO+ Model 8038 Respirator Fit Tester Theory of Operation (RFT-001)
 PORTACOUNT PRO+ Model 8038 Respirator Fit Tester Theory of Operation (RFT-001-A4)
 PORTACOUNT Theory of Operation (ITI-048)
 PortaCount® and EN 529 Standard
 Printing Fit Test Cards with an ID Card Printer (RFT-013)
 Printing Fit Test Cards with an ID Card Printer (RFT-013-A4)
 QLFT versus QNFT: Good…Better…Best (RFT-010)
 QLFT versus QNFT: Good…Better…Best (RFT-010-A4)
 Repairing CodeBase -200 Errors in FitPlus™ for Windows Fit Test Software v2.xx (ITI-069)
 Respirator Fit Testing Highlights for OSHA Respiratory Protection Standard 29CFR1910.134 (ITI-056)
 Standards and Regulations Pertaining to Respirator Fit Testing (ITI-046)
 Studies to confirm that PORTACOUNT® Pro and Pro+ Respirator Fit Tester give the same results as the PORTACOUNT® Plus Respirator Fit Tester (RFT-005-A4)
 The Essence of N95 Respirator Fit-Testing (RFT-006)
 Training Is The Key to a Good Fit Test Program (ITI-031)
 Troubleshooting Guide for the N95-Companion™ Model 8095 (ITI-084)
 Troubleshooting Guide for the PortaCount® Plus Model 8020 (ITI-083)
 US Military Test Protocols for FitPlus for Windows v. 2.xx (ITI-088)
 Using TSI Software on Computers that Do Not Have an RS-232 Serial Port (ITI-077)
 What You Need to Quantitatively Fit Test Various Brands of Self-Contained Breathing Apparatus Available in the USA (ITI-029)

CASE STUDIES

 Dissenting opinion: An ICP who favors fit-testing.

ICON FILES

 Model 8030 Icon File

MANUALS

 FitPro™ v1 Fit Test Software Manual
 FitPro™ v1 Fit Test Software Manual
 FitPro™ v1 Fit Test Software Manual
 FitPro™ v1 Fit Test Software Manual
 FitPro™ v2 Fit Test Software Installation Guide
 FitPro™ v2 Fit Test Software Manual
 Model 8026
 Model 8030/8038
 Model 8030/8038
 Model 8030/8038
 Model 8030/8038
 Modelle 8030, 8038
 PortaCount® Pro and PortaCount® Pro+ v1.2 Firmware Installation Guide
 v3.4 FitPlus™ Fit Test Software Manual

MSDS

 MSDS for Isopropyl Alcohol (90-100%)
 MSDS for Salt

SOFTWARE

 FitPlus™ v3 Demo Program
 FitPlus™ v3.4.4 Fit Test Software (11.4 MB)
 FitPro™ v2 Fit Test Software Upgrade (36.4 MB)

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Are the 0.04 micron particles used by the N95-Companion™ Mask Fit Tester appropriate for respirator fit testing?
  2. Are there any cleanroom applications for the PORTACOUNT® Respirator Fit Tester?
  3. Can I fit test with a respirator using chemical vapor cartridges?
  4. Can I lengthen the sampling hoses on the PORTACOUNT® Respirator Fit Tester?
  5. Can I use or test the PORTACOUNT® Respirator Fit Tester in a corn oil or DOP chamber?
  6. Can I use the PORTACOUNT® Respirator Fit Tester to find leaks in HEPA filters?
  7. Can I use the PORTACOUNT® Respirator Fit Tester to measure HEPA filter efficiency?
  8. Can the PORTACOUNT® Respirator Fit Tester be used to fit test disposable (filtering facepiece) respirators?
  9. Do exhaled moisture droplets affect the PORTACOUNT® Respirator Fit Tester?
  10. Do I have to remove the alcohol cartridge from my PORTACOUNT® Plus Respirator Fit Tester before I ship or store it? What happens if I forget?
  11. Do you need a probed mask?
  12. Does OSHA give employers a choice of using either qualitative (QLFT) or quantitative (QNFT) fit test methods?
  13. Does the PORTACOUNT® Respirator Fit Tester work with half-face and full-face respirators?
  14. Does the PORTACOUNT® Respirator Fit Tester work with powered air purifying respirators (PAPR's)?
  15. Does the PORTACOUNT® Respirator Fit Tester work with self contained breathing apparatus (SCBA) such as used by fire fighters?
  16. Does TSI sell PORTACOUNT® fit test software for the Apple® Macintosh® Computer?
  17. Don't ambient air particles get stuck in the person's lungs?
  18. Has the US Department of Energy (DOE) offered an official opinion on the PORTACOUNT® Respirator Fit Tester ?
  19. How come the Overall Fit Factor calculated by the PORTACOUNT® Respirator Fit Tester isn't the arithmetic average of the individual exercise fit factors?
  20. How come the PORTACOUNT® Respirator Fit Tester doesn't use a chamber?
  21. How do you clean masks in between fit tests?
  22. How does fit testing with an aerosol challenge agent relate to protection from gaseous hazards?
  23. How does the PORTACOUNT® Respirator Fit Tester work?
  24. How is the PORTACOUNT® Respirator Fit Tester affected by fluctuations in ambient particle levels?
  25. How long does an alcohol wick last in the PORTACOUNT® Plus Model 8020 Respirator Fit Tester?
  26. How long does it take to do a fit test with the PORTACOUNT® Respirator Fit Tester?
  27. How many exercises should we be using?
  28. How often does OSHA require workers to be fit tested?
  29. How often should the PORTACOUNT® Respirator Fit Tester be re-calibrated or cleaned?
  30. How often should the Zero Check and Max. Fit Factor Check be performed on the PORTACOUNT® Respirator Fit Tester?
  31. How quickly is the test subject supposed to move his/her head from side to side or up and down when performing the fit test exercises?
  32. I have an IBM-PC (or compatible) but I don't know if it is equipped with an RS-232 serial port. How can I tell?
  33. If I obtain my own reagent grade isopropyl alcohol, can I fill the PORTACOUNT® Respirator Fit Tester with it instead of buying TSI alcohol?
  34. If the PORTACOUNT® Respirator Fit Tester does not count all particles in the air, how can it work?
  35. I'm confused about the use of ambient air as the challenge agent. Please explain.
  36. Is the PORTACOUNT® Respirator Fit Tester intrinsically safe or explosion proof?
  37. Is there a way to test each person with their own mask rather than with a test mask?
  38. My company has strict requirements regarding the calibration of instruments.
  39. My company is having a hard time convincing male employees who wear tight-fitting respirators to shave their beards. Does TSI have any information on the subject?
  40. My SCBA uses grade-D breathing air. Isn't this particle free?
  41. OSHA requires positive-pressure respirators to be fit tested in negative-pressure mode. What do they mean?
  42. Should full-face masks be fit tested with the nose cup removed or left in place?
  43. The expense of quantitative fit testing instrumentation seems high compared to the cost of qualitative fit testing supplies. How can I justify this expense to my managers?
  44. The OSHA Respiratory Protection Standard 29CFR1910.134 requires a 15-second grimace exercise. Why is the data from that exercise ignored when the overall fit factor calculation is made?
  45. We always use a clean mask for each fit test to avoid spreading germs from person to person, but what about the moisture that collects in the PORTACOUNT® Respirator Fit Tester sample tube. Can someone be exposed to moisture from a previous test subject?
  46. We use chemical vapor cartridges in the factory. How does respirator fit using Class 100 (HEPA) cartridges relate to respirator fit with chemical cartridges?
  47. What about the ambient air particles that are trapped in the mask when it is donned?
  48. What are the size-fraction definitions for health-related sampling?
  49. What do inspirable, inhalable and total particles mean?
  50. What do you do if the test subject finishes reading the Rainbow Passage before the exercise is over?
  51. What does NIOSH think of the PORTACOUNT® Respirator Fit Tester?
  52. What does OSHA think of the PORTACOUNT® Respirator Fit Tester?
  53. What does the Nuclear Regulatory Commission (NRC) think of the PORTACOUNT® Respirator Fit Tester?
  54. What is a fit factor?
  55. What is a suitable substitute for the Rainbow Passage if the test subject cannot read or doesn't speak English?
  56. What is respirator fit testing?
  57. What is the particle size range in ambient air?
  58. What is the reason for fit testing respirators?
  59. What is the typical range of ambient particle concentrations?
  60. What particle size range can the PORTACOUNT® Respirator Fit Tester measure?
  61. What pass/fail level should my company use?
  62. What respirator types require fit testing according to OSHA?
  63. When a person fails the fit test, how do I know if the problem is the way the mask is worn, the size of the mask, a bad filter, or a defective mask?
  64. Where do I get probed masks and/or fit test adapters?
  65. Why do other fit test instruments need an aerosol generator and a chamber?
  66. Why does OSHA require fit testing of positive-pressure respirators? Isn't the leakage always in the "out" direction?
  67. Why is quantitative fit testing (QNFT) better than qualitative fit testing (QLFT)?
  68. Why should a person refrain from smoking for 30 minutes before being fit tested with the PORTACOUNT® Respirator Fit Tester?
  69. Why won't the PORTACOUNT® Respirator Fit Tester allow fit testing if the ambient particle count is below 1000 particles per cubic centimeter?
  70. Will the PORTACOUNT® Respirator Fit Tester work in a hazardous atmosphere?
  71. Will the PORTACOUNT® Respirator Fit Tester work properly with drug store variety isopropyl alcohol?