800-874-2811 | Contact Us
       
  • Language
FIND A DISTRIBUTOR OR REPRESENTATIVE
RELATED EVENTS
RELATED NEWS
3070A



ELECTRICAL AEROSOL DETECTOR 3070A

The Electrical Aerosol Detector 3070A (EAD) measures a key aerosol parameter believed to indicate the effective surface area of particles that can be deposited in the lung. This aerosol detector is a unique complement to our line of CPCs. Like a CPC, the EAD measures particle concentration as a function of time. But it also measures a parameter called aerosol diameter concentration, a property of ultrafine particles that is promising for health-effects research.

The EAD is a robust, low-cost, easy-to-use instrument that operates continuously and provides very fast measurements in the range from 10 to 1000 nm. It operates at a wide dynamic range, and it requires no working fluid or consumables. Plus, the EAD gives you unmatched reproducibility.

Features and Benefits

  • Measures particles from 10 to 1000 nm
  • Provides unmatched reproducibility
  • Designed for continuous, unattended operation
  • Requires no working fluid or consumables

Applications

  • Ambient aerosol monitoring
  • Combustion-generated particle studies
  • Epidemiological studies of human health effects
  • Inhalation and exposure studies
There are currently no items for this section.
There are currently no items for this section.

SERVICE INFORMATION

APPLICATION NOTES

 Emissions Monitoring Freeway Monitoring Performing Aerosol Science in Harm’s Way (EM-002)
 Emissions Monitoring Freeway Monitoring Performing Aerosol Science in Harm’s Way (EM-002--A4)
 Emissions Monitoring University of Minnesota Mobile Emission Laboratory (EM-001)
 Emissions Monitoring University of Minnesota Mobile Emission Laboratory (EM-001--A4)
 Running TSI’s Aerosol Instrument Manager® Software on a Macintosh® Computer (PR-003)
 Running TSI’s Aerosol Instrument Manager® Software on a Macintosh® Computer (PR-003-A4)

SERVICE PROCEDURES

 Model 3070A Standard Service Procedures

STANDARD REPLACEMENT PARTS

 Model 3070A Standard Replacement Parts

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Are there any special care precautions that must be taken before or during transportation?
  2. Can I communicate with the EAD remotely?
  3. Can the EAD detect very low concentration of aerosols, and how is the EAD different from a CPC?
  4. Does the EAD need coincidence correction at high concentrations?
  5. How does the EAD complement the Condensation Particle Counter (CPC)?
  6. Is the EAD suitable for fast-changing measurements?
  7. What is the parameter measured by the EAD and why is it important?
  8. Why is the diffusion charger unique in the EAD?