The  DUSTTRAK™ II Aerosol Monitor 8530 is a desktop battery-operated, data-logging, light-scattering laser photometer that gives you real-time aerosol mass readings. It uses a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance.

It is suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites, and other outdoor applications. The DUSTTRAK II Aerosol Monitor measures aerosol contaminants such as dust, smoke, fumes, and mists.

Features and Benefits

  • Measure aerosol concentrations corresponding to PM1, PM2.5, PM10 or Respirable size fractions
  • STEL alarm setpoint
  • Automatic zeroing (with optional zero module) minimizes the effect of zero drift
  • Perform in-line gravimetric analysis for custom reference calibrations
  • Manual and programmable data logging functions
  • Desktop Unit
  • Aerosol Concentration range 0.001 to 400 mg/m3

Applications

  • Industrial/occupational hygiene surveys
  • Indoor air quality investigations
  • Outdoor environmental monitoring
  • Baseline trending and screening
  • Engineering control evaluations
  • Remote monitoring
  • Process monitoring
  • Emissions monitoring
  • Aerosol research studies

Included Items

  • TRAKPRO™ Data Analysis Software
  • Li-Ion rechargeable batteries
  • Zero filter, AC adapter, impactors, cyclone
  • Operation Manual, Certificate of Calibration and carrying case
There are currently no items for this section.

Aerosol Monitor, Dust Monitor Environmental Enclosure

The custom designed, weatherproof Environmental Enclosure protects the DustTrak™ II and DRX Aerosol Monitor Models 8530, 8531, and 8533, TSI portable, battery-operated, laser photometers that measure and record airborne dust concentrations.

TRAKPRO™ Data Analysis Software

TRAKPRO™ Data Analysis Software is a Windows®-based software program that works with a variety of TSI data logging instruments. This unique software helps you pre-program instruments, store and organize your test data, and generate detailed graphs and reports needed to effectively communicate results.

SERVICE INFORMATION

APPLICATION NOTES

 Determining Custom Calibration Factors For Photometers (ITI-099)
 DUSTTRAK Alarm Output (ITI-074)
 DUSTTRAK Analog Output (ITI-073)
 DUSTTRAK II Aerosol Monitor and DUSTTRAK DRX Aerosol Monitor Impactor Penetration Efficiency Curves (EXPMN-003)
 DUSTTRAK II Aerosol Monitor Theory of Operation (EXPMN-001)
 DUSTTRAK II Aerosol Monitor Theory of Operation (EXPMN-001-A4)
 Getting Data You Need with Particle Measurement (ITI-075)
 Getting Data You Need with Particle Measurement (ITI-075-A4)
 Inlet Aspiration Efficiency of the DUSTTRAK Environmental Enclosure Model 8535 (ITI-060)
 Inlet Aspiration Efficiency of the DUSTTRAK Environmental Enclosure Model 8535 (ITI-060-A4)
 Measuring Total Suspended Particulates (TSP) with Aerosol Photometers (ITI-058)
 Research Papers Involving the TSI DUSTTRAK Aerosol Monitor (ITI-079)
 Using TSI Software on Computers that Do Not Have an RS-232 Serial Port (ITI-077)

MANUALS

  Model 8530,8532
  Model 8530,8532
  Modelle 8530, 8531, 8532
 Model 8535

SOFTWARE

 TRAKPRO™ Data Analysis Software v 4.4.0 (49 MB)

TECHNICAL NOTES

 Particle Size
 Particle Size Range for TSI Exposure Monitoring Instruments

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Can I adjust the alarm setpoint without using TRAKPRO™ software?
  2. Can I change the calibration constant to correspond to a different aerosol such as coal dust or oil mist?
  3. Can I measure respirable aerosol mass concentration with the DUSTTRAK™ Aerosol Monitor?
  4. Can I use a different cyclone filter on the DUSTTRAK™ Aerosol Monitor?
  5. Can I use the DUSTTRAK™ Aerosol Monitor for remote monitoring applications?
  6. Can I use the DUSTTRAK™ Aerosol Monitor outdoors?
  7. Can I use the DUSTTRAK™ Aerosol Monitor to determine when air system filters need to be changed or cleaned?
  8. Can logged data be transferred to another database or spreadsheet for reporting or data analysis?
  9. Can the Log 1, Log 2, and Log 3 modes be operating at the same time?
  10. Can we copy the software for use on other computers?
  11. Do statistics relate to the total time the instrument is turned on or only to the time sampling is taking place?
  12. How can I convert the DUSTTRAK™ Aerosol Monitor's 0-5 VDC analog output to a current output such as 4-20 mA?
  13. How do I tell if my DUSTTRAK™ Aerosol Monitor has the analog and alarm output features?
  14. How does sampling in high humidity affect the readings obtained from the DUSTTRAK™ Aerosol Monitor?
  15. How long can the cable be for transmitting the DUSTTRAK™ Aerosol Monitor's 0-5 VDC analog output?
  16. How long is the warranty on the DUSTTRAK™ Aerosol Monitor?
  17. How long will the DUSTTRAK™ Aerosol Monitor operate before the internal filter overloads in an environment containing 3-5 mg/m³ dust?
  18. How much data can be logged before the DUSTTRAK™ Aerosol Monitor runs out of memory?
  19. How often is calibration required?
  20. I purchased my DUSTTRAK™ Aerosol Monitor before the analog and alarm features were available. Can I upgrade my DUSTTRAK?
  21. If I need to have laboratory analysis performed to obtain independent data, how can the DUSTTRAK™ Aerosol Monitor help me?
  22. I'm not a computer expert. What is the easiest way to understand the software?
  23. Is logged data retained if I change the instrument batteries?
  24. Is the DUSTTRAK™ Aerosol Monitor intrinsically safe?
  25. What are the computer requirements for TRAKPRO Data Analysis Software?
  26. What are the differences between Log 1, Log 2, and Log 3 modes?
  27. What are the traceability specifications?
  28. What batteries are used in the DUSTTRAK™ Aerosol Monitor, and how long do they last?
  29. What does the TRAKPRO™ Data Analysis Software allow me to do?
  30. What happens if my batteries die during a measurement?
  31. What happens if the data logger memory becomes full?
  32. What happens to the analog output signal if the measured aerosol concentration exceeds the programmed scaling limit?
  33. What is the analog output resolution in volts per milligram/m³?
  34. What is the cost of the TRAKPRO software?
  35. What is the measurement range of the DUSTTRAK™ Aerosol Monitor?
  36. What is the warm-up time of the DUSTTRAK™ Aerosol Monitor?
  37. What length of sample tube can be used with the DUSTTRAK™ Aerosol Monitor?
  38. What type of device is the DUSTTRAK™ Aerosol Monitor?
  39. What U.S. standards or guidelines apply to ambient particulate levels in buildings?
  40. Where can I get a connector to mate with the 4-pin, mini-DIN output connector on the back of the DUSTTRAK™ Aerosol Monitor?
  41. Where do I find technical information on interfacing and using the DUSTTRAK™ Aerosol Monitor analog output and alarm functions?
  42. Will the DUSTTRAK™ Aerosol Monitor measure liquid aerosols such as water and oil?