8371



ACCUBALANCE AIR CAPTURE HOOD 8371

TSI's ACCUBALANCE® Air Capture Hood 8371 measures the air volume flowing through registers, diffusers, and grilles.

Weighing just seven and one half pounds, the ACCUBALANCE is easy to carry, lift, and use. Simply hold the ACCUBALANCE up to a diffuser or grill and read direct airflow of a supply or exhaust on the large digital display.

Applications include air volume measurements, thermal comfort, as well as HVAC testing, adjusting and balancing.

Features and Benefits

  • Variety of hood sizes
  • Sample and hold function displays reading of one sample
  • Automatic conversion between actual and standard flows
  • Field calibration adjustment
  • Variable time constant
  • K factor function
  • Back-lit display

Included Items

  • Base
  • battery holder and (4) C-size batteries
  • battery compartment cover
  • carrying case
  • operation and service manual
  • NIST calibration certificate
  • 2'x2' (610x610-mm) hood and frame hardware
There are currently no items for this section.
There are currently no items for this section.

SERVICE INFORMATION

APPLICATION NOTES

 Results of ACCUBALANCE® Air Capture Hood Testing at Tennessee Technological University (TI-122)

HANDBOOKS

 HVAC Assessment Handbook (2007)
 Indoor Air Quality Handbook (2011)
 Indoor Air Quality Handbook (2011-A4)

MANUALS

 Model 8371
 Modell 8371 Betriebs- und Wartungshandbuch

SOFTWARE

 LOGDAT™ for Windows® v2.13.00 (software download)

FREQUENTLY ASKED QUESTIONS

show/hide all answers
  1. Can I buy one hood for the ACCUBALANCE® Air Capture Hood?
  2. Can the ACCUBALANCE® Air Capture Hood read to zero CFM?
  3. Does the hot-wire sensor need to be cleaned in the field to assure accurate readings?
  4. How long is the warranty period?
  5. How much does the ACCUBALANCE® Air Capture Hood weigh?
  6. How often should I have the ACCUBALANCE® Air Capture Hood calibrated?
  7. Is it back-pressure compensated?
  8. What about this LIGHT key?
  9. What are the sensor considerations for high temperature flows?
  10. What does the ACCUBALANCE® Air Capture Hood measure?
  11. What does the ACCUBALANCE® Air Capture Hood use for power?
  12. What is the accuracy of an ACCUBALANCE® Air Capture Hood?
  13. What is the repeatability of TSI instruments?
  14. What is the typical construction of a hot-film sensor for use in water?
  15. What is the typical construction of a hot-wire sensor?
  16. What range of flow can it measure?
  17. What temperatures can it be used in?
  18. When are cylindrical hot-film sensors recommended for use?
  19. When are hot-wire sensors recommended for use?
  20. When using the ACCUBALANCE® Air Capture Hood, do you need to correct for altitude?
  21. When using the ACCUBALANCE® Air Capture Hood, do you need to correct for temperature?
  22. Why are the ends of the hot-wire sensor plated?
  23. Why do I have to select supply or return during my measurement?
  24. Why doesn't TSI's instrument agree with my other instruments?