Protection from exposure to hazardous material is a crucial component in terms of worker safety. As occupational health concerns rises as a priority, exposure assessment and monitoring of engineered nanoparticles is becoming increasingly important.

Many businesses regularly conduct exposure monitoring as a way of evaluating workplace health and safety conditions, especially as they relate to a worker’s exposure to chemical, physical and biological hazards while they are on the job.

TSI manufactures lines of exposure monitoring systems designed to detect airborne dust and aerosol mass concentrations. If you need real-time environmental or indoor air quality monitoring, TSI has the instruments for you. Our company also makes the AM510 personal aerosol monitors; these instruments are designed to measure and monitor dust concentrations in one’s personal work zone.

Our equipment is thoroughly tested and highly effective, helping us earn a reputation for making the best exposure monitoring instruments available. Our products are very useful in assisting in selecting and implementing effective workplace engineering controls and determining the need and limitations of personal protective equipment.

Contact TSI today to learn more about our industry-leading exposure monitoring instruments.

RELATED NEWS
INTRODUCING DUSTTRAK II AND DRX AEROSOL MONITORS — June 1, 2008-  TSI Incorporated announces the worldwide introduction of the DUSTTRAK™ II and DRX Aerosol Monitors. The new DUSTTRAK II and DRX Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. TSI HELPS INVESTIGATE AIR QUALITY AT BEIJING 2008 OLYMPICS — July 18, 2008- TSI Inc. is supporting the air quality monitoring efforts for the Beijing Olympic Games by providing multiple measurement instruments to sports stadiums, foreign newspapers, TV news stations and research organizations at the 2008 Olympics in Beijing, China. During the bidding process in 2001, Beijing made the agreement with the International Olympic Commission to bring air quality within the World Health Organization standards. Pollution levels remain one of the biggest challenges for the Olympic Games and some athletes have spoken of withdrawing from events because of the health threat.TSI INCORPORATED AWARDED GSA CONTRACT WITH THE US FEDERAL GOVERNMENT — January 1, 2009 -- TSI Inc. has been awarded a GSA (General Services Administration) Multiple Award Schedule contract, GS-07F-0428U, with the US Federal Government. This schedule 66 contract allows TSI’s government customers to streamline their purchasing of TSI instruments and services. Some of the TSI products available through the GSA contract include the ACCUBALANCE® Air Capture Hoods, AEROTRAK™ Handheld Particle Counters, Certifier FA ventilator tester, IAQ-CALC™ Meter, PORTACOUNT® Respirator Fit Tester, P-TRAK® Ultrafine Particle Counter, and the VelociCalc Series Multi-Function Ventilation Test Instrument.TSI SUPPORTS OIL SPILL RESPONSE —   TSI INC RECEIVES ISO RECERTIFICATION WITH ZERO NONCONFORMANCE ISSUES — April 27, 2011 - TSI Incorporated is pleased to announce the ISO 9001:2008 Standard recertification of its Shoreview, Minnesota facility.  Spanning three and a half days, the in-depth ISO audit performed by BSI reviewed the quality management system in great detail.  In addition to achieving recertification, TSI proudly reports that zero nonconformance findings were issued.  TSI INC HOSTS PRESIDENT OF THE CHINESE ACADEMY OF SCIENCES —  TSI DUSTTRAK™ USED TO MONITOR FRAC-SAND MINES IN WESTERN WISCONSIN — September 23, 2011 - As frac-sand mines open in Chippewa County (Western Wisconsin) for oil and gas refinery, TSI's DUSTTRAK™ will serve as an important tool for assessing environmental impacts and air quality. Already, researchers at University of Wisconsin- Eau Claire have used the DUSTTRAK to track the presence of minute silica particles in the air- common with this type of mining.
RELATED EVENTS
There are currently no items for this section.
RELATED PROMOTIONS
There are currently no items for this section.
APPLICATION NOTES
 AEROTRAK 9000 Nanoparticle Aerosol Monitor Theory of Operation (ITI-100-A4)
 Determining Custom Calibration Factors For Photometers (ITI-099)
 DUSTTRAK Alarm Output (ITI-074)
 DUSTTRAK Analog Output (ITI-073)
 DUSTTRAK DRX Aerosol Monitor Calibration Methods (EXPMN-005)
 DUSTTRAK DRX Aerosol Monitor Calibration Methods (EXPMN-005-A4)
 DUSTTRAK DRX Aerosol Monitor Theory of Operation (EXPMN-002)
 DUSTTRAK DRX in Environmental Applications (EXPMN-006)
 DUSTTRAK DRX in Environmental Applications (EXPMN-006-A4)
 DUSTTRAK II Aerosol Monitor and DUSTTRAK DRX Aerosol Monitor Impactor Penetration Efficiency Curves (EXPMN-003)
 DUSTTRAK II Aerosol Monitor Theory of Operation (EXPMN-001)
 DUSTTRAK II Aerosol Monitor Theory of Operation (EXPMN-001-A4)
 DUSTTRAK Theory of Operation (ITI-036)
 Health-Based Particle-Size-Selective Sampling (ITI-050)
 How A Virtual Impactor Works (ITI-051)
 Inlet Aspiration Efficiency of the DUSTTRAK Environmental Enclosure Model 8535 (ITI-060)
 Inlet Aspiration Efficiency of the DUSTTRAK Environmental Enclosure Model 8535 (ITI-060-A4)
 Mass Concentration Comparison Between the DUSTTRAK DRX Aerosol Monitor and TEOM (EXPMN-004)
 Measuring Total Suspended Particulates (TSP) with Aerosol Photometers (ITI-058)
 New Approaches and Technologies in Personal Sampling Pumps (ITI-089)
 QLFT versus QNFT: Good…Better…Best (RFT-010)
 QLFT versus QNFT: Good…Better…Best (RFT-010-A4)
 Research Papers Involving the TSI DUSTTRAK Aerosol Monitor (ITI-079)
 Serial Data Acquisition With the DUSTTRAK Model 8520 (ITI-044)
 SIDEPAK AM510 Personal Aerosol Monitor Theory of Operation (ITI-085)
 SIDEPAK™ NiMH Battery Maintenance (ITI-092)
 SIDEPAK™ NiMH Battery Maintenance (ITI-092-A4)
 Using TSI Software on Computers that Do Not Have an RS-232 Serial Port (ITI-077)
 What does NIOSH Consider as Acceptable Reference Technologies for Primary Calibrators? (ITI-090)
BROCHURES
 DUSTTRAK™ II and DRX Aerosol Monitors Family Brochure
 DUSTTRAK™ II and DRX Aerosol Monitors Family Brochure
 Indoor Air Quality Measurements Family
 Indoor Air Quality Measurements Family (A4)
 SIDEPAK™ Personal Sampling Pumps
CALIBRATION CERTIFICATE
 SIDEPAK Flowmeter Calibration Certificate
MANUALS
  Model 8530,8532
 Model 4046/4146
 Model 8520
 Model 8533 and 8534
 Model 8535
 Model AM510 User Guide
 Models SP330/SP350 User Guide
 Models SP530/SP730 User Guide
MODEL COMPARISON GUIDE
 Model Comparison Chart - SidePak Pumps
QUICK GUIDES
 4046 Quick Guide
 4146 Quick Guide
 SIDEPAK SP730 Bypass Guide
 SIDEPAK™ AM510 Quick Reference Card
 SIDEPAK™ NiMH Battery Maintenance
 SIDEPAK™ SP330/350 Quick Reference Card
 SIDEPAK™ SP530 Quick Reference Card
 SIDEPAK™ SP730 Quick Reference Card
SOFTWARE
 TRAKPRO™ Data Analysis Software v 4.4.0 (49 MB)
SPEC SHEETS
 Model 8535
 Model 8535
 Modelo 8535
 Modelos 8530 y 8532
 Modelos 8533 y 8534
 Models 8530/8532
 Models 8530/8532
 Models 8530/8532 (A4)
 Models 8533 and 8534
 Models 8533 and 8534
 Primary Calibrators
 SIDEPAK™ AM510
 SIDEPAK™ AM510 (A4)
 SIDEPAK™ SP330
 SIDEPAK™ SP330 (A4)
 SIDEPAK™ SP350
 SIDEPAK™ SP350 (A4)
 SIDEPAK™ SP530
 SIDEPAK™ SP530 (A4)
 SIDEPAK™ SP730
 SIDEPAK™ SP730 (A4)
TECHNICAL NOTES
 Particle Size
 Particle Size Range for TSI Exposure Monitoring Instruments