800-874-2811 | Contact Us
       
  • Language

PIV SPRAY DIAGNOSTICS

Sprays are an important part of our everyday life, from pharmaceutics to food production, and from automobiles to airplanes. TSI Spray Diagnostics products help to keep all these spray processes running at peak efficiency by ensuring desired system operation or by pinpointing where the spray system is not performing as designed.

 

Phase Doppler systems measure droplet size and velocity and provide detailed statistics with high spatial resolution. Traversing the PDPA system gives size and velocity field of the spray.

 

Imaging-based Spray Analysis systems, using INSIGHT™ 3G software package, provide rapid image-based data on spray patternation, size, and symmetry. Even pulsed sprays can be analyzed using an easy-to-use external trigger and phase-lock feature of the imaging-based system.

 

In addition, PIV systems provide rapid, visual, velocity based data over the entire flowfield. This allows immediate feedback on the "big-picture" analysis of the spray structure. High Frame Rate PIV systems provide rapid characterization of the evolution of transient sprays, including velocities, vorticity, power spectra, and other flow properties.

RELATED NEWS
TSI’S V3V SYSTEM RESULTS ON YOUTUBE.COM — February 17, 2009 - For the first time, you can now view TSI’s V3V System demo and results on Youtube.com. TSI ANNOUNCES 2011 SEMINARS AND WEBINARS FOR RESEARCH AND ANALYTIC APPLICATIONS —   TSI INC RECEIVES ISO RECERTIFICATION WITH ZERO NONCONFORMANCE ISSUES — April 27, 2011 - TSI Incorporated is pleased to announce the ISO 9001:2008 Standard recertification of its Shoreview, Minnesota facility.  Spanning three and a half days, the in-depth ISO audit performed by BSI reviewed the quality management system in great detail.  In addition to achieving recertification, TSI proudly reports that zero nonconformance findings were issued. 
RELATED EVENTS
June 25, 2012 –
June 28, 2012
International Symposium of Flow Visualization 2012
Minsk, Belarus
Visit TSI at the Show
July 09, 2012 –
July 12, 2012
16th Int. Symposium Lisbon 2012
The Calouste Gulbenkian Foundation Lisbon, Portugal
Visit TSI at the Show Booth No#9
RELATED PROMOTIONS
2011 PDPA/LDV TRADE-IN PROGRAM — TSI has extended the PDPA and LDV trade in program through 2011.  Receive a generous 20% off when you trade in any IFA, DSA, or RSA based signal processor and get a generous allowance on new FSA based hardware, including FlowSizer software. This is the complete FlowSizer software package, not a stripped down version. Your measurements will get a performance boost with the FSA 3500 or FSA 4000, while cost of ownership will drop dramatically. Start measuring those bursts down to 50ns transit time, rather than letting them slip away. 
APPLICATION NOTES
 Experimental Study on the Flow Characteristics of Streamwise Inclined Jet in Crossflow
 Flame Characterization Under Microgravity Conditions (PIV-001)
 Flame Stabilization
 Flow behind a Mitral Valve
 Flow Measurements in a Microchannel
 Hovering Helicopter Rotor Wake
 Measurements around Insect Wings
 Measurements In a High Reynolds Number Swirling Flow
 Measurements in a Large Chamber
 Measurements in a Lifted-Jet Flame
 Measurements in a Microchannel
 Measurements in a Motored Internal Combustion Engine
 Measurements In a Swirling Air Flow
 Measurements in a Turbulent Channel Flow
 PIV Measurements of the Asymmetric Wake of a Two-dimensional Heaving Airfoil
 Propeller-wake Study (StereoPIV-006)
 Quantification of Laminar Mixing Performance using Laser-Induced Fluorescence
 Taylor-Couette Flow
 The Effect of Gurney Flap Height on Vortex Shedding Modes Behind Symmetric Airfoils
 Time Resolved PIV Analysis of Flow Over a NACA 0015 Airfoil with Gurney Flap PIV-014
 Turbomachinery - Measurements in a Transonic Axial Compressor
 Two-phase Bubbly Flow Measurements
 Water Flow Downstream of a Body (StereoPIV-007)
BROCHURES
 Cameras for PIV, PLIF, and GSV
 Cameras for PIV, PLIF, and GSV
 Combustion Diagnostics Using Planar Laser-Induced Fluorescence
 Expert Measurement Alliance Program
 FSA™ Multi-bit Digital Processors
 Global Imaging Systems
 Global Sizing Velocimetry (GSV) System
 High Frame-Rate PIV Systems
 INSIGHT 3G™
 INSIGHT 4G™ Software Platform A4
 INSIGHT 4G™ Software Platform US
 Measuring Microflows Using Particle Image Velocimetry
 Multi-Phase Flow
 PDPA LDV Family Brochure
 POWERVIEW™ PIV/PLIF Systems
 Proper Orthogonal Decomposition (POD)
 Super Resolution Particle Velocimetry
MODEL COMPARISON GUIDE
 Model Comparison Chart - Insight 3G
 Model Comparison Chart - LDV MultiBit Digital
 Model Comparison Chart - PDPA MultiBit Digital Burst
 Model Comparison Chart - PIV LaserPulse Synchronizer
 Model Comparison Chart - Powerview Cameras
 Model Comparison Chart - Powerview Plus Cameras
POSTERS
 PIV Poster
SERVICE PROCEDURES
 Model 3433 Standard Service Procedures
SPEC SHEETS
 1.4 MP
 FLOWSIZER™ 2.0 Data Acquisition and Analysis Software Update—for Windows XP
 FLOWSIZER™ 3.0 Software
 High Frame Rate Cameras
 HS-200
 HS-2000
 HS-3000
 HS-650
 HYPERSTREAMING™ Image Transfer System
 IC Engine Probe Adaptors Models EP-12 and EP-14
 INSIGHT 3G™ The Complete, Powerful and Accurate Software Package for Global Image Acquisition, Analysis, and Display for Fluid Mechanics Research
 INSIGHT 4G™ Software Platform A4
 INSIGHT 4G™ Software Platform US
 INSIGHT 4G™ The Complete, Powerful and Accurate Software Package for Global Image Acquisition, Analysis, and Display for Fluid Mechanics Research
 LASERPULSE™ Synchronizer Model 610034
 LaserPulse™ Synchronizer Model 610035
 Model 11MP
 Model 2MP
 Model 4MP
 Model 610048 MicroPIV Optical Assembly
STANDARD REPLACEMENT PARTS
 Model 3433 Standard Replacement Parts
TECHNICAL NOTES
 How Frame-Straddling Works