|
|
PIV SYSTEM PIV/PLIF
The integrated PIV/PLIF system from TSI is a unique, on-line diagnostic tool that lets a TSI system simultaneously measure global scalar property fields (e.g., temperature, concentration) along with the two- or three-component velocity field.
A laser sheet illuminates the measurement region and the PIV camera captures Mie-scattered light to determine the velocity field. Fluorescence is collected on a dedicated PLIF camera. The relationship between fluorescence intensity and scalar properties obtained from calibration is used to convert the PLIF image field into the scalar quantity of interest.
Simultaneous PLIF and PIV measurements can be used to evaluate mass transfer rates, heat transfer rates, and mixing processes. Dynamic links to MATLAB® and Tecplot® software packages provide a higher level of capability and flexibility in data analysis and display. Other features of the integrated PLIF/PIV package include a dual camera housing, complete software control of all hardware components, image processing, field alignment, just to name a few. For more information, please see the attached literature or contact a TSI representative.
Features and Benefits
- Measures flow velocity and global scalar property fields simultaneously
- Choice of different cameras for PIV and PLIF imaging
- Simultaneous or sequential PIV and PLIF measurements
- Use of INSIGHT™ 3G Data Acquisition, Analysis and Display Software affords maximum flexibility in data acquisition and display
- Unique, in-situ PLIF calibration process can be performed under actual experimental conditions
- Choice of lasers to match the application
Applications
- Combustion diagnostics
- Mass and heat flux measurements
- Contaminant transport
- Mixing processes
Included Items
- Double pulse Nd:YAG laser (50 mJ/pulse standard, higher pulse energy available as upgrade option)
- Additional PLIF laser (required for PLIF measurements not using YAG harmonic)
- CCD camera for PIV with frame-straddling (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
- CCD camera for PLIF (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
- INSIGHT™ 3G-PIVLIF Data Acquisition, Analysis and Display Software Package with PLIF and PIV capabilities
- Light sheet optics (and optional Laser Light Arm)
- Optical filters (PIV filter, specific PLIF filter depends on species being measured)
- LASERPULSE™ Synchronizer (Model 610035)
- All associated manuals
To request more information about TSI's Particle Image Velocimetry (PIV) System, including a price quotation, a system demo, product literature, etc. click here.
To learn more about PIV instrumentation and the many areas of research this system is involved in, attend TSI's Fluid Mechanics Webinar Series presented by our experts. Visit www.tsi.com/FMwebinars.
 |
INSIGHT™ 3G-PIVLIF software package processes PIV and PLIF image capture, analysis and display software on .NET platform. |
 |
INSIGHT™ 3G-2DTR software package process PIV image capture, analysis and display software on .NET platform |
 |
INSIGHT™ 3G-Global software package process Stereo PIV, PLIF and Global Spray image capture, analysis and display software on .NET platform
|
 |
TSI LASERPULSE Mini-YAG Laser Model YAG120-BSL |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG15-15 |
 |
TSI LASERPULSE YAG Laser Model YAG190-BSL |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG30-15 |
 |
TSI LASERPULSE Mini-YAG Laser Model YAG50-15 |
 |
The LASERPULSE Synchronizer Model 610035 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. |
.jpg) |
LASERPULSE Synchronizer Model 610036 The LASERPULSE Synchronizer Model 610036 from TSI is a programmable master timing control unit for use in Particle Image Velocimetry (PIV) applications. Acting as the master controller for system components, it automates control of the timing between laser pulses, camera, camera |
 |
TSI’s LASERPULSE Light Arm is an articulated arm that offers flexibility in delivering the light sheet for PIV measurements or for other high energy laser applications. |
 |
Laser light sheet optics from TSI provide flexibility in the light sheet divergence angle and the beam waist location via careful selection of focal lengths. for PIV and PLIF applications. |
 |
TSI's POWERVIEW™ 1.4MP Camera offers 1376 × 1040 pixel resolution and 12-bit intensity dynamic range, short frame straddling times, and long exposure times for PIV and PLIF applications. |
.jpg) |
TSI POWERVIEW™ Plus 11MP Camera is a multi-bit, 11-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 2MP Camera is a multi-bit, 2-megapixel, digital CCD camera designed exclusively for global flow measurements. |
.jpg) |
TSI POWERVIEW™ Plus 4MP Camera is a multi-bit, 4-megapixel, digital CCD camera designed exclusively for global flow measurements. |
 |
POWERVIEW™ Plus HS-200 Camera has 640 × 480 pixel resolution, 12-bit intensity dynamic range, along with high image capture rates up to 500 frames per second. |
 |
TSI offers a full range of optical filters, which are a critically important component of PIV and PLIF system, ensuring that the correct wavelength of light is collected by the CCD camera and that other wavelengths are rejected. |
 |
High output fog generator for LDV and PIV seeding with large scale wind tunnels, HVAC equipment, and other high flow devices. |
 |
TSI Laser Power Meters provide a convenient and accurate way to measure Ar ion beam powers, to keep your LDV or PDPA system running at peak efficiency. |
 |
TSI Laser Laser Safety Goggles provide a solid protection from direct and scattered laser beams. We take the guesswork out of selection and purchase of Ar ion, YAG, and YLF safety eyewear, so you can focus on using the system. |
 |
TSI's PIV Mount Kits provide a user-friendly and rugged but precise mounting base for your PIV camera(s). Easy adjustment and long-term stability are the key features of the TSI PIV Mount Kits. |
 |
The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows. |
 |
TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used. |
 |
TSI offers a full range of seed particles to satisfy even the most difficult measurement requirements. Available in a full range of materials and sizes, TSI seed particles maximize the potential of PIV and LDV systems. |
 |
TSI's Model 9302 single-jet atomizer generates a polydisperse aerosol stream from a compressed air source. External pressure control and a flexible outlet tube allow the user to put the right amount of aerosol right where its needed. |
 |
The Six-Jet atomizer from TSI is used to generate a polydisperse aerosol in high concentrations, which can be used as seed particles for PIV and LDV measurements. External controls adjust the number of active jets and dilution air flow rate. |
 |
Traverse accessories help the user get the most productivity out of their TSI traverse, while enhancing safety of operation. |
 |
Single Axis (1D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. These traverses are also used for capturing size and velocity profiles in a flow with a FLOWSIZER™ |
.jpg) |
TSI T2D and T2DE Two Axis (2D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis System. |
 |
Three Axis (3D) Heavy-duty Traverse Systems are used for capturing size and velocity profiles in a flow with a three-component FLOWSIZER™ software-based LDV or phase Doppler system. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with TSI INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
 |
Three Axis (3D) Traverse Systems are used for capturing image data at multiple planes in a flow with INSIGHT™ 3G software-based PIV, HFR-PIV, PLIF, or Spray Analysis systems. |
BROCHURESPOSTERSSPEC SHEETSSERVICE INFORMATION
APPLICATION NOTESTECHNICAL NOTES
|
|