800-874-2811 | Contact Us
       
  • Language

APPLICATION OF AERODYNAMICS

The ability to obtain detailed velocity measurements and associated flow properties enables designers to enhance the aerodynamics of bodies and vehicles, from airplanes, ships and automobiles to micro-size devices.

 

Thermal anemometers provide accurate velocity measurements including velocity spectrum and higher order statistics in clean gas and liquid flows. LDV systems use laser beams to get accurate velocity measurements in gas and liquid flows, even in hostile environments. They also make non-invasive measurements in rotating machinery, especially, in the interblade region in compressors, turbines and fans.

 

PIV systems use a laser sheet to measure the instantaneous flow field in a desired region. Measurements provide vorticity, spatial velocity gradients and other variations. Repeated PIV measurements provide time-averaged statistics. Time-resolved measurements capture the temporal variation of the velocity field. PIV/PLIF systems add scalar properties (pressure, temperature, etc.).

 

TSI CERTIFIER® semi-portable wind tunnels have a small test section ideal for flow measurements on small devices or for air velocity sensor testing/analysis and test instrument calibration.

RELATED NEWS
TSI ANNOUNCES 2011 SEMINARS AND WEBINARS FOR RESEARCH AND ANALYTIC APPLICATIONS —   TSI ACQUIRES QUANT TECHNOLOGIES, LLC ASSETS AND INTELLECTUAL PROPERTY — September 24th, 2010 -- TSI Incorporated, a worldwide leader in aerosol measurement technology, is pleased to announce the acquisition of Quant Technologies’ water-based condensation particle counter (WCPC) assets and intellectual property. Production and service of the existing line of WCPCs will be transferred to TSI’s ISO 9001 certified facility in Shoreview, MN.   TSI INC RECEIVES ISO RECERTIFICATION WITH ZERO NONCONFORMANCE ISSUES — April 27, 2011 - TSI Incorporated is pleased to announce the ISO 9001:2008 Standard recertification of its Shoreview, Minnesota facility.  Spanning three and a half days, the in-depth ISO audit performed by BSI reviewed the quality management system in great detail.  In addition to achieving recertification, TSI proudly reports that zero nonconformance findings were issued. 
RELATED EVENTS
May 18, 2012 –
May 18, 2012
Cambridge Particle Meeting UK 2012
Cambridge, UK
Visit TSI at the Show
RELATED PROMOTIONS
2011 PDPA/LDV TRADE-IN PROGRAM — TSI has extended the PDPA and LDV trade in program through 2011.  Receive a generous 20% off when you trade in any IFA, DSA, or RSA based signal processor and get a generous allowance on new FSA based hardware, including FlowSizer software. This is the complete FlowSizer software package, not a stripped down version. Your measurements will get a performance boost with the FSA 3500 or FSA 4000, while cost of ownership will drop dramatically. Start measuring those bursts down to 50ns transit time, rather than letting them slip away. 
APPLICATION NOTES
 Airfoil Wake (V3V-003)
 Automobile Wake (V3V-007)
 Experimental Study on the Flow Characteristics of Streamwise Inclined Jet in Crossflow
 Flame Characterization Under Microgravity Conditions (PIV-001)
 Flame Stabilization
 Flow behind a Mitral Valve
 Flow Measurements in a Microchannel
 Forced Convection Airflow in an Enclosure (V3V-010)
 High Speed Particle Size Measurements (LDV-001)
 Hovering Helicopter Rotor Wake
 LDV Measurements In A Boundary Layer (LDV-002)
 LDV Measurements in an IC Engine using a Spark Plug Mounted Probe (LDV-006)
 Measurements around Insect Wings
 Measurements In a High Reynolds Number Swirling Flow
 Measurements in a Large Chamber
 Measurements in a Lifted-Jet Flame
 Measurements in a Microchannel
 Measurements in a Motored Internal Combustion Engine
 Measurements In A Shock Tube Flow (LDV-003)
 Measurements In a Swirling Air Flow
 Measurements in a Turbulent Channel Flow
 Measurements of Rotor Tip Vortices Using Three-Component Laser Doppler Velocimetry (LDV-004)
 PIV Measurements of the Asymmetric Wake of a Two-dimensional Heaving Airfoil
 Propeller Wake (V3V-004)
 Propeller-wake Study (StereoPIV-006)
 Quantification of Laminar Mixing Performance using Laser-Induced Fluorescence
 Round Jet (V3V-002)
 Simulated Fish (V3V-009)
 Smoothly Contoured Ramp and Vortex Generators (V3V-005)
 Sphere Wake (V3V-006)
 Survey Of A Wake Field (LDV-005)
 Taylor-Couette Flow
 The Effect of Gurney Flap Height on Vortex Shedding Modes Behind Symmetric Airfoils
 Time Resolved PIV Analysis of Flow Over a NACA 0015 Airfoil with Gurney Flap PIV-014
 Turbomachinery - Measurements in a Transonic Axial Compressor
 Turbulent Flow in Stirred Tank Reactors (V3V-008)
 Two-phase Bubbly Flow Measurements
 Vortex Ring (V3V-001)
 Water Flow Downstream of a Body (StereoPIV-007)
BROCHURES
 Cameras for PIV, PLIF, and GSV
 Cameras for PIV, PLIF, and GSV
 Combustion Diagnostics Using Planar Laser-Induced Fluorescence
 Fiber Optic Probes for PDPA/LDV Systems
 FSA™ Multi-bit Digital Processors
 Global Imaging Systems
 Global Sizing Velocimetry (GSV) System
 High Frame-Rate PIV Systems
 INSIGHT 3G™
 INSIGHT 4G™ Software Platform A4
 INSIGHT 4G™ Software Platform US
 Measuring Microflows Using Particle Image Velocimetry
 Multi-Phase Flow
 POWERVIEW™ PIV/PLIF Systems
 Proper Orthogonal Decomposition (POD)
 Standard Traverse Systems for LDV, PDPA and PIV
 Super Resolution Particle Velocimetry
 V3V™ System Extensive Capabilities Brochure
 Volumetric 3-Component Velocimetry (V3V) brochure
CATALOGS
 TSI Thermal Anemometry Probes
MODEL COMPARISON GUIDE
 Model Comparison Chart - Insight 3G
 Model Comparison Chart - LDV MultiBit Digital
 Model Comparison Chart - PDPA MultiBit Digital Burst
 Model Comparison Chart - PIV LaserPulse Synchronizer
 Model Comparison Chart - Powerview Cameras
 Model Comparison Chart - Powerview Plus Cameras
MSDS
 MSDS for Fluorescent Microspheres, Dyed Microspheres
 MSDS for Glass Oxide Coated with Silver, Metallic Coated Particles
 MSDS for Glass Oxide, Nylon Particles
 MSDS for Glass Oxide, Spherical Glass Powder
 MSDS for Metal Oxide, Titanium Dioxide
 MSDS for Polystyrene Uniform Latex Particles
 MSDS for Silicon Carbide
 MSDS for Silver Metal Coated Glass
POSTERS
 PIV Poster
SERVICE PROCEDURES
 Model 3321 Standard Service Procedures
 Model 3321 Upgrade Standard Service Procedures
SPEC SHEETS
 1.4 MP
 fiberlight™ Multicolor Beam Generator
 FLOWSIZER™ 2.0 Data Acquisition and Analysis Software Update—for Windows XP
 FLOWSIZER™ 3.0 Software
 High Speed Pulsed YAG Laser Model D-YAG-HS
 HS-200
 HS-2000
 HS-3000
 HS-650
 HYPERSTREAMING™ Image Transfer System
 IC Engine Probe Adaptors Models EP-12 and EP-14
 INSIGHT 3G™ The Complete, Powerful and Accurate Software Package for Global Image Acquisition, Analysis, and Display for Fluid Mechanics Research
 INSIGHT 4G™ Software Platform A4
 INSIGHT 4G™ Software Platform US
 INSIGHT 4G™ The Complete, Powerful and Accurate Software Package for Global Image Acquisition, Analysis, and Display for Fluid Mechanics Research
 LASERPULSE™ Synchronizer Model 610034
 LaserPulse™ Synchronizer Model 610035
 Model 11MP
 Model 2MP
 Model 4MP
 Model 610048 MicroPIV Optical Assembly
 Models 9307 and 9307-6 Oil Droplet Generators US
 PDM Scattered Light Separation and Photodetector System
 Seed Particles for LDV and PIV
 TSI Mini-Fiber Probes TR110/TR210 Series
 V3V 9000
STANDARD REPLACEMENT PARTS
 Model 3321 Standard Replacement Parts
TECHNICAL NOTES
 A/D Board Driver Becomes Corrupt
 Advantages to the Look-up Table Approach of Voltage-Velocity Conversion In Thermal Anemometry
 Correcting for non-orthogonal Measurements
 Correction of Gradient Errors in Thermal Anemometry
 Data Capturing and Analysis in ThermalPro
 Definition of TSI Calibration Curve
 Format of ThermalPro Binary Files
 Hot-Wire Calibration in ThermalPro
 How EMI can affect your Hotwire Anemometry System
 How Frame-Straddling Works
 How to Set the Zero Offset of the A/D Card
 How to Use External Connector Board
 Measured Velocity has Drift
 Measured Velocity Jumps when Changing IFA300 Modes
 Non-Cylindrical and -60 Probe Setup
 Oscillation in the Signals
 Parts for 1050 Series Systems
 Resolution of Hot-Wire Anemometry Measurements
 Running the IFA300 with my own Data Acquisition System
 Selecting the Coincidence Window for a Multichannel LDV System
 Temperature Correction in ThermalPro: How it Works
 The Difference Between Data Rate and Data Density
 Thermal Anemometry Probe Contamination
 ThermalPro will not allow Velocity to be Analyzed
 Thermocouple Specifications for Hot-Wire Anemometry
 Tuning a Model 183150 CTA Module
 Using a USB to Serial Port Device with ThermalPro and the IFA300
 Using Custom Software and Hardware rather than ThermalPro
 Wall Effects in Thermal Anemometry
 What is the Shorting Cap and Shorting Probe?